Level limits of the DiscreteControl-controlled Outlets and Pumps.

Functions

Name Description
bound_supply_inflows Limit the aanvoer control state of inflows into a controlled Basin to the target level of that Basin.

bound_supply_inflows

capacity.bound_supply_inflows(model, target_level_column='meta_streefpeil')

Limit the aanvoer control state of inflows into a controlled Basin to the target level of that Basin.

A supplying Outlet or Pump without a max_downstream_level can fill the Basin it supplies far above its target level, as long as its DiscreteControl does not switch, which is up to a day with a daily control interval.

Parameters

Name Type Description Default
model Model model with DiscreteControl-controlled Outlets and Pumps required
target_level_column str column of the Basin / area table with the target level 'meta_streefpeil'

Returns

Name Type Description
list[int] the node IDs that got a max_downstream_level