capacity
capacity
Level limits of the DiscreteControl-controlled Outlets and Pumps.
Functions
| Name | Description |
|---|---|
| bound_supply_inflows | Limit the aanvoer control state of inflows into a controlled Basin to the target level of that Basin. |
bound_supply_inflows
capacity.bound_supply_inflows(model, target_level_column='meta_streefpeil')Limit the aanvoer control state of inflows into a controlled Basin to the target level of that Basin.
A supplying Outlet or Pump without a max_downstream_level can fill the Basin it supplies far above its target level, as long as its DiscreteControl does not switch, which is up to a day with a daily control interval.
Parameters
| Name | Type | Description | Default |
|---|---|---|---|
| model | Model | model with DiscreteControl-controlled Outlets and Pumps | required |
| target_level_column | str | column of the Basin / area table with the target level | 'meta_streefpeil' |
Returns
| Name | Type | Description |
|---|---|---|
| list[int] | the node IDs that got a max_downstream_level |