Control

Most Outlets and Pumps in the regional models are controlled by a DiscreteControl node. Each has one of these functions, which decides when it lets water through, and the code that adds them is in ribasim_nl.control:

This is what they do in terms of upstream and downstream levels, in the supply (aanvoer) or drain (afvoer) state:

Function Dutch State determined by Flow in supply state [m³/s] Flow in drain state [m³/s] Nodes added
drain uitlaat upstream level 0 capacity DiscreteControl
supply inlaat downstream level capacity 0 DiscreteControl
flow_control doorlaat upstream and downstream level capacity capacity DiscreteControl
flushing doorspoeling upstream level and flow rate demand capacity DiscreteControl and FlowDemand

Each controlled node gets two rows in its static table, for the control states aanvoer (supply) and afvoer (drain), and one DiscreteControl node with a control link. The capacity in the table is max_flow_rate: a node lets through its flow_rate, limited by max_flow_rate. Flushing nodes also get a FlowDemand node, which sets the flow to maintain, seasonal if it differs between summer and winter; their flow_rate in the supply state is 0.

flowchart LR
  up["Basin upstream"] -->|flow| outlet["Outlet<br>afvoer: capacity<br>aanvoer: 0"]
  outlet -->|flow| down["Basin downstream"]
  dc["DiscreteControl"] -.->|control| outlet
  up -.->|listens to level| dc

A drain node between two Basins. The DiscreteControl node listens to the level upstream and switches the state of the Outlet.

Levels and thresholds

The target level of a Basin is its meta_streefpeil in Basin / area. From it follow the thresholds of the DiscreteControl nodes and the level limits of the nodes:

  • The thresholds have a band of 5 cm in total around the level (DEFAULT_LEVEL_THRESHOLD_RANGE), so a node does not keep switching.
  • min_upstream_level is the target level upstream, and in the supply state 4 cm below it, except for drain nodes, which keep the target level in both states.
  • max_downstream_level in the supply state is the target level downstream.
  • In the drain state, Pumps stop pumping into a Basin 20 cm above its target level (MAALSTOP_LEVEL_OFFSET). Outlets are limited by gravity, so they have no such limit.

The summer and winter levels later split each state into a winter and a summer variant, such as afvoer zomer.

How nodes get their function

The two kinds of models get their function differently.

  • Gravity controlled: 04_add_full_control.py calls add_controllers_to_supply_area for each supply area, verwerkt/sturing/aanvoergebieden.gpkg. The inlets and outlets of the polygon, and lists by hand, give the function: inlets supply and outlets drain, the reverse of a supply or flow control node drains, downstream of supply nodes it is flow_control, and the rest drains, except the reverse of a drain node, which supplies. Then add_controllers_to_uncontrolled_connector_nodes handles the remaining Outlets and Pumps, without those in exclude_nodes. The priority is flushing, flow control, drain, supply; the rest again drains, except the reverse of a drain node.
  • Level controlled: the meta_categorie of a node maps to a function, with exceptions in set_node_functions. This gives no flushing nodes.

Exceptions

Some systems need more than a DiscreteControl node per connector:

  • Noorderzijlvest and Wetterskip Fryslân use set_continuous_level_control in places.
  • Rijnland uses set_discrete_level_control, with control states stap n.
  • Aa en Maas, Limburg and Rijnland also add FlowDemand nodes in their own scripts. In Rijnland, Katwijk flushes at least 1.07 m³/s this way.
  • The main water system has its own control with DiscreteControl, ContinuousControl and FlowDemand nodes, see Main water system.

Capacities

The capacity of a node is its max_flow_rate. In the gravity controlled models it comes from the reviewed static_data.xlsx, with flow_rate_mm_per_day as the default by node type and function, and flow_rate is often higher, so max_flow_rate decides. The level controlled models set the unknown capacities from the area they drain or supply, and their flow_rate to the same value, see design capacities.